Understanding Air Venting in Hydronic Boiler Systems

Air in Hydronic Boiler Systems: A Comprehensive Guide

Air trapped in hydronic boiler systems can severely impact efficiency, performance, and reliability. When air enters the water loop, it can cause noises, reduce heat transfer, and disrupt the circulation of water. In this comprehensive article, we'll cover:

  1. Symptoms of Air in the Boiler System
  2. Impact of Trapped Air on Boiler Performance
  3. Types of Air Venting Devices
  4. Techniques for Troubleshooting and Resolving Air-Related Issues
  5. Preventative Measures to Avoid Air in the System

1. Symptoms of Air in the Boiler System

Air trapped in the system can manifest in several ways, including:

  • Gurgling or Hissing Noises: As water flows past air pockets, it creates these distinctive sounds.
  • Cold Spots in Radiators or Baseboards: Uneven heating is often due to air preventing water from reaching certain sections.
  • Erratic Pressure Gauge Readings: Fluctuations in system pressure may indicate trapped air.
  • Reduced Heating Efficiency: Air in the system acts as an insulator, reducing heat transfer efficiency.
  • Frequent Pump Failures: Circulator pumps struggle to move water when air is present.
  • System Lockout: Modern boilers may shut down as a safety precaution when air disrupts normal operation.


2. Impact of Trapped Air on Boiler Performance

Trapped air creates several operational issues:

  • Decreased Efficiency: Air reduces water flow and heat transfer, leading to increased energy consumption.
  • Corrosion Risks: Oxygen in trapped air can accelerate corrosion within the system.
  • Component Stress: Pumps and valves work harder, reducing their lifespan.
  • Imbalanced Heat Distribution: Poor heating performance results in discomfort and inconsistent room temperatures.

3. Types of Air Venting Devices

Efficient air removal requires specialized devices. Below are common types:

a. Manual Air Vents (Bleed Valves)

  • Found on radiators and at high points in the system.
  • Require manual operation to release air.
  • Best suited for smaller systems or for periodic air removal.

b. Automatic Air Vents

  • Operate without manual intervention.
  • Equipped with a float mechanism that opens a valve when air is present and closes it when water reaches the vent.
  • Commonly installed near boilers, at system high points, or on manifolds.


c. Air Separators

  • Designed for high-efficiency air removal.
  • Use centrifugal force or baffles to separate air from water.
  • Ideal for larger systems with significant air challenges.


d. Microbubble Air Eliminators

  • Remove dissolved air and microbubbles before they form larger pockets.
  • Installed in the main loop to ensure continuous air removal.
  • Often paired with automatic air vents.
Air vent device illustration


Note the Spirovent completely eliminates 100% of the free air, 100% of the entrained air, and up to 99.6% of the dissolved air in the system. It consists of woven copper wire soldered to a copper tube, the Spirotube creates a low velocity area in the Spirovent that scrubs the bubbles from the water. The air bubbles rise and collect in the air chamber before they are vented from the system via an integral automatic valve.

Note: fluid velocity is an art and savvy HVAC experts use medium velocities to improve performance of systems. Case in point, reduce air velocity in air filters.

4. Troubleshooting and Resolving Air-Related Issues

When air problems arise, systematic troubleshooting is essential:

Step 1: Identify Air Presence

  • Check Noises: Listen for gurgling sounds in radiators or pipes.
  • Inspect Radiators: Feel for cold spots, typically at the top, which indicate trapped air.
  • Monitor Pressure: Fluctuations in the boiler's pressure gauge can signal air.

Step 2: Bleed the System

  1. Turn off the Boiler: Allow the system to cool before working on it.
  2. Locate Bleed Valves: Open manual vents on radiators or high points.
  3. Release Air: Turn the bleed valve slowly and let the air escape until water flows steadily.
  4. Repressurize: If necessary, add water to the system to restore the correct pressure.

Step 3: Check Automatic Air Vents

  • Inspect for blockages or malfunctioning float mechanisms.
  • Replace faulty units if they fail to remove air.

Step 4: Examine Air Separators

  • Verify proper installation and maintenance.
  • Clean any internal components that might be clogged.

Step 5: Verify Circulation

  • Confirm that the circulator pump is functioning correctly.
  • Air can cause cavitation, damaging the pump; repair or replace as needed.

5. Preventative Measures to Avoid Air in the System

Preventing air entry and accumulation ensures a more reliable system. Consider these tips:

  1. Regular Maintenance: Schedule routine hot water boilers maintenance to catch issues early.
  2. System Design: Ensure proper pipe slopes and vent placements to encourage air removal.
  3. Check Expansion Tanks: A faulty expansion tank can allow air into the system. Inspect and maintain it regularly.
  4. Seal Leaks: Even small leaks can introduce air; repair them promptly.
  5. Install High-Quality Air Eliminators: Investing in effective air removal devices minimizes manual intervention.

Conclusion

Air in a hydronic boiler system is a common but manageable problem. By understanding the symptoms, employing the right air venting devices, and following systematic troubleshooting techniques, you can restore optimal performance and efficiency. Regular maintenance and preventative measures are key to ensuring long-term reliability and comfort.